Machine Control Output Destination

If Use External Synchronization in the Transport menu is activated, all transport commands (including movements of the cursor in the Project window) are translated into machine control commands and routed according to the settings that are made in the Machine Control Output Destination section.

No Machine Control

If this option is selected, transport commands are not routed or sent to any device. This does not affect the operation of the individual 9-Pin and MMC Device panels. They can still function regardless of the machine control destination. The machine control output destination only defines the routing of transport commands from Nuendo while sync is enabled.

MIDI Machine Control

If this option is selected and sync is enabled, all transport commands from the Nuendo transport are routed to MMC devices connected to the MIDI ports that you defined in the “Machine Control Output Settings” section.

9-Pin Control 1 and 2

When one of the 9-Pin Control options is selected and sync is enabled, transport commands from Nuendo are routed to the 9-Pin Device 1 or 2, as configured in the “Machine Control Output Settings” section.

Steinberg ‘Time Base’ and Steinberg SyncStation

If this option is selected and sync is enabled, transport commands from Nuendo are routed to a connected Time Base or Steinberg SyncStation unit (respectively). Please refer to the documentation that comes with your unit for complete information on its operation.