Unloading Unused Samples

The RAM Save function scans the playback of your project and unloads unused samples.

Procedure

  1. Click RAM Save on the toolbar and in the dialog, click Yes to start collecting the necessary samples.

    The RAM Save button starts blinking.

  2. Play back the project in your host application from the beginning to the end or to the point where no new notes are played.

    RAM Save always keeps samples that are within the range between the highest and the lowest note of the played programs. This also applies for unused expression layers that can be controlled via key switches. This allows you to switch between expressions within the valid note range after applying RAM Save mode.

    Important

    If a program randomly triggers notes, for example, different guitar slide noises, it is possible that these notes are not triggered during the RAM Save analysis process, and that the samples are therefore removed. To prevent this, trigger the highest required note manually during the analysis.

  3. Click the RAM Save button again. In the dialog, click Yes.

Result

The unused samples are unloaded.